HOW FAST IS FAST ENOUGH?

“How rapidly should I test my input signal?” is a genuinely basic question among DAQ system originators, and particularly those without formal preparing in either DAQ systems or test hypothesis. The straightforward answer is the system must example sufficiently quick to “see” the required changes in input. In an absolute input system, the base required specimen rate is commonly characterized by Nyquist inspecting hypothesis. Nyquist found that to reproduce a waveform, you

Read More

THERMAL EXPANSION/CONTRACTION ISSUES

A few writings regard the initial two things as a similar impact. All things considered, if the coefficients of the development of the gage and the thing under test are the same, they will contract or grow at similar rates in light of a temperature change. For this situation, an adjustment in system temperature would not bring on any adjustment in the demonstrated strain, with the exception of that in

Read More

TEMPERATURE MEASUREMENTS

Temperature is more likely than not the most ordinarily measured marvel in data acquisition. Regardless of whether the application is far below the ocean, on the interstate, noticeable all around, or in profound space, temperature assumes a key part in numerous systems. The most widely recognized temperature sensors are the Thermocouple, the RTD (Resistance Temperature Detector), the Thermistor, and the Semiconductor temperature sensor. Whole books have been composed with respect

Read More

GAIN ERROR AND DIFFERENTIAL NON-LINEARITY

Gain Error  It is least demanding to delineate this error by first accepting every single other error are zero. Pick up error is the distinction in the slant (in volts per bit) between the genuine system and a perfect system. For instance, if the pickup error is 1%, the pickup error at 1 volt would be 10 millivolts (1 * .01), while the error at 10 volts would be ten

Read More

ANALOG INPUTS AND A/D CONVERTERS

The analog input is the foundation of the data acquisition showcase. In spite of the fact that other I/O ports play key parts in numerous applications, by far most of DAQ systems incorporate analog input and a decent percentage of they require just analog input.  We will characterize analog input by avoidance. Any input that is not computerized, that is not characterized as two states, (e.g., high/low or one/zero) will

Read More

STRAIN (& STRESS) MEASUREMENTS

The Strain Gage (a.k.a. Strain Gage) is a standout amongst the most normally measured gadgets in data acquisition and DAQ systems. The strain is frequently measured as the real parameter of intrigue. On the off chance that the application is really keen on how much a protest grows, contracts, or winds, the coveted estimation is a strain. The strain is likewise as often as possible measured as a moderate intends to

Read More

CALCULATE THE ERROR AND ELIMINATE IT MATHEMATICALLY

On the off chance that you know the genuine distinction in coefficients of warm extension between the strain gage and the part being tried, it’s hypothetically conceivable to numerically kill the error brought about by changes in temperature. Obviously, to do this, you likewise need to gauge the temperature precisely at the strain gage establishment. The strain gage development coefficients, in any case, are not for the most part accessible

Read More

PC-BASED DAQ SYSTEMS

PC-based DAQ systems are accessible with a wide assortment of interfaces. Ethernet, PCI, USB, PXI, PCI Express, Firewire, Compact Flash and even the respected GPIB, RS-232/485, and ISA transport are all prominent. Which one(s) is/are the most fitting for a given application might be a long way from self-evident. Maybe the primary question to address while considering another DAQ venture is whether the application is best served by a module board system

Read More

BE CAREFUL WITH REGISTRATIONS

We found a memory development in their application which utilized client occasions for interprocess correspondence. The issue we found was that any client occasions which are enrolled however unhandled by an occasion structure will expand your application’s memory use when produced.  A fundamentally the same as the issue was raised at the 2011 CLA summit that produced CAR 288741 (settled for LabVIEW 2013). This CAR was recorded in light of

Read More

IOT AND DATA: PART 2

The second part is here, you didn’t wait for too long, did you? This article will address the other two problems we think IoT and DAQ will face in the future. Problem 2: The average client utilizes three to five document sorts for undertakings.  With such a large number of custom arrangements available, your present application likely includes an assortment of sellers to finish your assignment. Now and again these sellers oblige

Read More